SEL-487B

SEL-487B

Bus Differential and Breaker Failure Relay
  • The SEL-487B provides a comprehensive protection solution, including high-speed low-impedance bus differential protection, circuit breaker failure protection, and backup overcurrent protection. A single relay can protect up to seven terminals, and the system is flexibly designed to expand up to 21 terminals when multiple relays are used in parallel. It is a core device optimized for modern digital substations, supporting SEL’s Digital Secondary System (DSS) technologies, such as TiDL (Time-Domain Link) and Sampled Values (SV).

Key Features

  • High-Speed Differential Protection (87)

    Operates in less than one cycle for busbar differential protection, increasing system stability and minimizing equipment damage.
  • Up to Six Independent Protection Zones

    Provides up to six independent and adaptable differential protection zones within a single relay system, covering complex busbar configurations.
  • Wide Range of Inputs

    Features 21 analog current inputs and three analog voltage inputs to accommodate large-scale busbar systems.
  • CT Ratio Mismatch Compensation

    Accommodates CT ratio mismatches as high as 35:1 through internal settings, eliminating the need for auxiliary CTs.
  • Failed CT Detection

    Reliably indicates open or shorted CT conditions for alarming and/or blocking to prevent misoperation.
  • External Fault Security Logic

    Incorporates advanced security algorithms to prevent misoperation caused by CT saturation during external faults.
  • Integrated Backup and Breaker Failure Protection

    Provides instantaneous and time-overcurrent elements as well as independent breaker failure detection for all terminals.
  • Digital Substation Technology Support

    TiDL Technology: Simplifies wiring by transmitting data via fiber-optic cables.
    Sampled Values (SV): Supports digital data streams according to IEC 61850-9-2 or IEC 61869-9 standards.

Convenience features

  • Advanced Metering and Monitoring

    Provides voltage, current, phase data, and real-time power metering, including monitoring for station DC battery systems.
  • Precision Event Analysis

    Enables clear analysis of pre- and post-fault conditions through high-resolution event reports and Sequential Events Recorder (SER) functions.
  • Synchrophasors

    Supports wide-area system monitoring by providing phasor measurement data compliant with the IEEE C37.118 standard.
  • Diverse Communication Protocols

    Supports FTP, Telnet, DNP3, PRP, PTPv2, and IEC 61850 Edition 2.1 (optional) for easy integration with supervisory systems.
  • Flexible Port Configuration

    Offers various Ethernet card options, including copper (RJ45) or fiber-optic (SFP), alongside standard EIA-232 serial ports.
  • Precise Time Synchronization

    Supports PTPv2 and IRIG-B inputs for microsecond-level time synchronization.
  • SEL Grid Configurator Support

    Efficiently manages complex busbar settings and logic configurations through intuitive, modern software.