SEL-787Z

SEL-787Z

High-Impedance Differential Relay and SEL-HZM High-Impedance Module
  • The SEL-787Z is a flexible protection relay designed primarily for high-impedance bus protection. It provides a high-speed, cost-effective solution for busbars and is also suitable for motor protection or sensitive Restricted Earth Fault (REF) protection on grounded, wye-connected power transformer windings. When combined with the dedicated SEL-HZM High-Impedance Module, it creates a stable and robust differential protection system.

Key Features

  • High-Impedance Differential Protection (87V)

    Designed to provide ultra-fast tripping for in-zone faults while maintaining high security during heavy through-faults and CT saturation.
  • SEL-HZM Module Integration

    Uses a dedicated module with built-in stabilizing resistors and Metal-Oxide Varistors (MOVs) to protect CT wiring and the relay against high-voltage surges during in-zone faults.
  • Comprehensive Overcurrent Protection

    Independent overcurrent elements can be used to complement high-impedance differential elements, providing multiple layers of protection.
  • Voltage Protection Elements

    Includes undervoltage (27) and overvoltage (59) elements to detect abnormal voltage-based conditions.
  • Arc-Flash Protection

    Supports arc-flash detection elements (TOL1–TOL8) with a very fast pickup time of 2–5 ms, minimizing equipment damage and risk to personnel.
  • Precise Sampling

    Processes data with high precision at a rate of 40 samples per cycle for 60 Hz systems and 48 samples per cycle for 50 Hz systems.

Convenience features

  • 5-inch Color Touchscreen Display

    An optional large color screen allows for direct on-site system monitoring and setting configuration, supporting multiple languages including English and Spanish.
  • Broad Protocol Support

    Easily integrates into existing automation systems with support for IEC 61850 Edition 2, DNP3, EtherNet/IP, Modbus TCP/RTU, FTP, and Telnet.
  • Network Reliability

    Supports Parallel Redundancy Protocol (PRP) and Rapid Spanning Tree Protocol (RSTP) to ensure continuous data transmission even during communication path failures.
  • Precision Event Analysis

    Features Sequential Events Recorder (SER) and high-resolution event reporting to help clearly analyze the root cause of disturbances.
  • Precise Time Synchronization

    Provides microsecond-level timing accuracy through IEEE 1588 PTP and IRIG-B inputs.